Greetings-

We upgraded our operating system to z/os 1.11 last fall.  We have IPL'd
our Production System twice since then, and each time, we have caused
our AUTO1 task to fail on our Test System.  Last week, we IPL'd our test
system, and the AUTO1 task dropped on our Production system. Once
recovered, we IPL'd our Test system several more times, and never lost
AUTO1.  

The messages that we are seeing are for our EE link between the two
system to go down,  ( as we are IPLing. . . . )
 and then these Messages:

MVS2     12134 01:17:32.40 STC35551 00000281  DSI769I MVS02 RPL_EXIT
APPCCMD RECEIVE FAILED, LUNAME = MVS01, QUALIFY = 
                                                X'11', FEEDBACK =
(X'4C',X'00',X'80020000')                             
 MVS2     12134 01:17:32.40 STC35551 00000281  DSI769I MVS02 RPL_EXIT
APPCCMD SEND FAILED, LUNAME = MVS01, QUALIFY =    
                                               X'07', FEEDBACK =
(X'4C',X'00',X'80020000')                              
 MVS2     12134 01:17:32.40 STC35551 00000281  DWO575I RMTCMD TERMINATED
ON CSNET.MVS01 WITH SENSE: X'08A80012'         
 MVS2     12134 01:17:32.40 STC35551 00000281  DSI769I MVS02 RPL_EXIT
APPCCMD ALLOC FAILED, LUNAME = MVS01, QUALIFY =   
                                               X'1F', FEEDBACK =
(X'04',X'00',X'087D0001')                              
 MVS2     12134 01:17:32.44 STC35551 00000290  IEA631I  OPERATOR AUTO12
NOW INACTIVE, SYSTEM=MVS2    , LU=AUTO1       

If anyone else has had this issue, I would appreciate your insight.