Thanks for your help.
I changed region parameter. But
System is not allowing me to change DPRTY to 1980. So I left it as old one.
(13,13). but still same error.
STMT NO. MESSAGE
2 IEFC001I PROCEDURE NETVSSI WAS EXPANDED USING SYSTEM LIBRARY
TIVOLI.PR
IEF695I START NETVSSI WITH JOBNAME NETVSSI IS ASSIGNED TO USER SYSSTC ,
GROUP
IEA995I SYMPTOM DUMP OUTPUT
SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011
TIME=09.33.22 SEQ=00099 CPU=0000 ASID=0051
PSW AT TIME OF ERROR 078D1000 00008746 ILC 4 INTC 11
ACTIVE LOAD MODULE ADDRESS=000078D8 OFFSET=00000E6E
NAME=CNMINIT
DATA AT PSW 00008740 - 001058E0 908C5810 E1DC5910
Regards
Saurabh
On Thu, Nov 24, 2011 at 3:15 PM, Ted MacNEIL <[email protected]> wrote:
>
> >PGM=CNMINIT,TIME=1440,REGION=6144K,PARM=(8192,2048,'%','SYSTEM','PPI','*NOARM'),
> DPRTY=(13,13)
>
> Two things:
>
> 1. Why such a small region? IBM has recommended REGION=0M for aeons. This
> could be a cause of the 0C4.
>
> 2. Specifying DPRTY is so 1980.
>
> -
> Ted MacNEIL
> [email protected]
> Twitter: @TedMacNEIL
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
>
--
Thanks & Regards
Saurabh Khandelwal
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html