> Scott Ford said:
>
> What about this:
> //COND2 EXEC PGM=TCOND,PARM=11
> //A
> Allen:
> 
> What about this:
> //COND2 EXEC PGM=SETCOND,PARM=U111
> //AA SET ABENDCC=U0111
> // IF (COND2.RUN=TRUE OR COND2.&ABENDCC=U0111) THEN
> 
> Scott J Ford

I think you've misunderstood.  My problem is not with creating a return code; 
that's very easy.  (As I said, we have a trivial utility that does it just 
fine.)

My problem is how to use either IF statements, or CONDs (IF statements 
preferred), to allow a job to continue if a particular step abends, but to 
flush remaining steps if any further step abends.

Regards,
Allen

----------------------------------------------------------------------