On Wed, 17 Nov 2010 13:49:21 +0100, Rafal Hanzel <[email protected]>
wrote:

>I didn't configure any NPIV
>
>>> for PCHID 111
>>>   Device   Subchannel
>>>   Number      Set        S_ID      Target WWPN    D_ID        Status
>>>    5100           0       0062562B  500604.....     00AE549C   Port Open
>>> and It works perfectly
>>>
>>> for PCHID 113
>>> Device   Subchannel
>>>   Number      Set        S_ID      Target WWPN       D_ID      Status
>>>    5200           0       00E2562B  0000000000000000  00AE548C   PLOGI Error
>>>    ****           *       0062562B  500604.....       00AE549C   Port Closed

I think you will need to look at enabling NPIV. In your display, target WWPN
of 500604 appears for both PCHID 111 and 113. The following info may be
useful (http://www.redbooks.ibm.com/abstracts/redp4125.html?Open)
.
Hope this helps
.
Roger

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to