On Tue, Sep 28, 2010 at 5:04 PM, Jacky Bright <[email protected]>wrote:
> Yes. I am getting following error > > IDCAMS SYSTEM SERVICES TIME: > > DELETE - > WRHC.UCS.UCAHST.ACTIVE.HISTORY.DATA- > FILE(DD1) - > VVR > IDC3014I CATALOG ERROR > IDC3009I ** VSAM CATALOG RETURN CODE IS 90 - REASON CODE IS IGG0CLFP-46 > IDC0551I ** ENTRY WRHC.UCS.UCAHST.ACTIVE.HISTORY.DATA NOT DELETED > IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 8 > > IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 8 > > On Tue, Sep 28, 2010 at 4:59 PM, O'Brien, David W. (NIH/CIT) [C] < > [email protected]> wrote: > > > Jacky, > You need to specify the master catalog in the CATALOG parameter. Jim McAlpine ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html