Ian Lance Taylor wrote:
Boris Boesler <[EMAIL PROTECTED]> writes:The following code generators use FOR_EACH_BB[_REVERSE] in the target machine dependent reorg pass: - bfin - frv - ia64 - mt - s390 Are these invalid code generators then? Or are we talking about different things?Yes, they are probably broken.
Not if they call compute_bb_for_insn at the start of their reorg pass. Bernd -- This footer brought to you by insane German lawmakers. Analog Devices GmbH Wilhelm-Wagenfeld-Str. 6 80807 Muenchen Sitz der Gesellschaft Muenchen, Registergericht Muenchen HRB 40368 Geschaeftsfuehrer Thomas Wessel, William A. Martin, Margaret Seif