External Email - Use Caution        

Hello,

I am running freesurfer v7.3.2 reconall with -synthseg on a pediatric sample, 
and for one specific subject I keep getting a lot of gray matter classified as 
white matter, which leads to the ?h.white surfaces being too close to the pial 
surface. I have tried running with and without the --robust option but the 
issue recurs. Are there any expert options that I can play with before manually 
editing the WM.mgz? The issue is pervasive throughout the brain so will require 
heavily editing every single slice. The values for the misclassified gray 
matter are 85-97 in the brainmask.mgz and 100-110 in the WM.mgz and the T1 
image looks ok by eye. When trying to run the same subject with the default 
pipeline (no synthseg), it crashes with the following error:

reading 1 input volumes...
logging results to talairach.log
reading 
'/share/software/user/open/freesurfer/7.3.2/average/RB_all_2020-01-02.gca'...
GCAread took 0 minutes and 1 seconds.
average std = 7.2   using min determinant for regularization = 5.2
0 singular and 884 ill-conditioned covariance matrices regularized
reading 'nu.mgz'...
error: mghRead(/MYPATH/freesurfer/sub-2341/mri/brainmask.mgz, -1): could not 
open file
error: mri_em_register: could not open mask volume brainmask.mgz.

I wonder if there's any parameter I can tweak in the expert.opts?
Thanks for any leads,
Maya
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
Please note that this e-mail is not secure (encrypted).  If you do not wish to 
continue communication over unencrypted e-mail, please notify the sender of 
this message immediately.  Continuing to send or respond to e-mail after 
receiving this message means you understand and accept this risk and wish to 
continue to communicate over unencrypted e-mail. 

Reply via email to