External Email - Use Caution Thanks! I will try it.
Kind Regards, Andy (Junghyun) Kim ________________________________ From: freesurfer-boun...@nmr.mgh.harvard.edu <freesurfer-boun...@nmr.mgh.harvard.edu> on behalf of Douglas N. Greve <dgr...@mgh.harvard.edu> Sent: Thursday, April 6, 2023 11:43 AM To: freesurfer@nmr.mgh.harvard.edu <freesurfer@nmr.mgh.harvard.edu> Subject: Re: [Freesurfer] How to create a functional ROI on surface where activation is peak? If you know what the vertex number is, you can do something like mri_volsynth --dim-surf fsaverage/surf/lh.white --pdf delta --delta-crsf vertexno 0 0 0 --o delta.mgh mris_fwhm --i delta.mgh --o delta.sm3.mgh --s fsaverage --hemi lh mri_binarize --i delta.sm3.mgh --min 0.5 --o delta.sm3.bin.mgh delta.sm3.bin.mgh will be a binary disk approximately 3mm in radius On 4/4/2023 7:24 AM, Andy Kim wrote: External Email - Use Caution Dear FreeSurfer developers, Hi. I've always appreciated your help. I am writing this email to kindly ask you how to create a functional ROI where activation (which is a result of FS-FAST) is peak. In volume-based analysis, people often make a "3mm-sphere" seed around peak activation for connectivity analysis. But since it is surface based, there is no "3mm-sphere". Then what would it be for surface? I tried: mri_surfcluster --in ./masked_sig1.nii.gz --hemi lh --subject fsaverage --thmin 5 --sum ./summary1.txt, but its output is not actually what I want. It tells peak X, Y, Z coordinates, but I want a fixed size of small cluster (like 3mm-sphere in volume) for creating a ROI in different masks (like peak ROI in V1, peak ROI in V2, etc). In addition, minimum threshold may be diffrent depending on masks. By this I mean, if I choose thmin of 5 for both V1 and V2, V1 may have a huge cluster where vertices have values greater than 5, where as V2 may have a small cluster. I just want to get a fixed size of ROI around "peak". How should I make a functional ROI around peak activation on surface? Kind Regards, Andy (Junghyun) Kim _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu<mailto:Freesurfer@nmr.mgh.harvard.edu> https://secure-web.cisco.com/1IBAZbhW_NPeQ4Oy0s68BOjkI_QHW0QmIorjGpEADD9wDf2Jp_-EKpykl4lEUBuW_6729ZTlHBRlQO_4pEOWyWoakOsXr-vF1kkNJ6lm1FSAG_a-w46Kyamvtdh4uTRzlDK_DI5LyTwS2WxjCN_39cVztb-BMivz3tcBSYkbV4eH5tWLuzo0bw9aVMubcpZUi4e8EembVDKs3R0-m8oFn6fPC-IYDJdauNcD4ERejNRTYh9gWiWGro7tiyUnpzq_2Dk6Cl2vLcehCMwkUopjmOXZTM9rt2k2yW28CSrqMJcN_8tAoEOOUzftGzJgivgZg/https%3A%2F%2Fmail.nmr.mgh.harvard.edu%2Fmailman%2Flistinfo%2Ffreesurfer
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Mass General Brigham Compliance HelpLine at https://www.massgeneralbrigham.org/complianceline <https://www.massgeneralbrigham.org/complianceline> . Please note that this e-mail is not secure (encrypted). If you do not wish to continue communication over unencrypted e-mail, please notify the sender of this message immediately. Continuing to send or respond to e-mail after receiving this message means you understand and accept this risk and wish to continue to communicate over unencrypted e-mail.