External Email - Use Caution Dear experts,
I report an answer you gave about some negative values avatar partial volume correction: "[...] Usually this only happens in small ROIs and/or low uptake regions. Why might the model not be perfect? It could be a number of things: 1. the MRI-PET registration is inaccurate 2. the MRI segmentation is inaccurate 3. the ideal segmentation is not reflected by the MRI segmentation (eg, one of the segmentations has a hot spot)" I wonder if it is possible for you to give me an hint about the reason why an inaccurate registration or segmentation can cause negative uptake values. At first sight it seemed intuitive to me, but on second thought that's not so obvious. I would be very grateful for any help! Federica Di Antonio
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Mass General Brigham Compliance HelpLine at https://www.massgeneralbrigham.org/complianceline <https://www.massgeneralbrigham.org/complianceline> . Please note that this e-mail is not secure (encrypted). If you do not wish to continue communication over unencrypted e-mail, please notify the sender of this message immediately. Continuing to send or respond to e-mail after receiving this message means you understand and accept this risk and wish to continue to communicate over unencrypted e-mail.