External Email - Use Caution        

What scans are these?  I wasn’t aware of any 0.5mm scans.

Matt.

From: <freesurfer-boun...@nmr.mgh.harvard.edu> on behalf of Trisanna 
Sprung-Much <trisanna.sprung-m...@mail.mcgill.ca>
Reply-To: Freesurfer support list <freesurfer@nmr.mgh.harvard.edu>
Date: Thursday, January 21, 2021 at 12:21 PM
To: Freesurfer support list <freesurfer@nmr.mgh.harvard.edu>
Subject: Re: [Freesurfer] HCP T1w scans on FreeSurfer 7.1





        External Email - Use Caution
Hi there

As a follow-up to this question, I tried the flags as stated and the recon-all 
seems to have failed at the inflation stage:

/data-01/trisanna/freesurfer/freesurfer_7.1.1/TEST2/scripts

 mris_sphere -q -p 6 -a 128 -seed 1234 ../surf/lh.inflated.nofix 
../surf/lh.qsphere.nofix

doing quick spherical unfolding.
limitting unfolding to 6 passes
using n_averages = 128
setting seed for random number genererator to 1234
version: 7.1.1
available threads: 1
scaling brain by 0.274...
inflating...
Command terminated by signal 11
@#@FSTIME  2021:01:21:08:13:01 mris_sphere N 9 e 4.07 S 0.18 U 3.72 P 95% M 
281092 F 17 R 136514 W 0 c 337 w 22 I 4312 O 0 L 1.00 1.00 1.00
@#@FSLOADPOST 2021:01:21:08:13:06 mris_sphere N 9 1.00 1.00 1.00
Linux kaplan 4.15.0-132-generic #136~16.04.1-Ubuntu SMP Tue Jan 12 18:22:20 UTC 
2021 x86_64 x86_64 x86_64 GNU/Linux

recon-all -s TEST2 exited with ERRORS at Thu Jan 21 08:13:06 EST 2021



Any advice would be greatly appreciated,

Trisanna
________________________________
From: freesurfer-boun...@nmr.mgh.harvard.edu 
<freesurfer-boun...@nmr.mgh.harvard.edu> on behalf of Trisanna Sprung-Much 
<trisanna.sprung-m...@mail.mcgill.ca>
Sent: Tuesday, January 19, 2021 6:05 PM
To: Freesurfer support list <freesurfer@nmr.mgh.harvard.edu>
Subject: [Freesurfer] HCP T1w scans on FreeSurfer 7.1


        External Email - Use Caution
Hi there

If I want to run some HCP subjects that are 0.5mm iso T1w scans (MPRAGE) in 
FreeSurfer 7.1, would I simply use the following flags, or am I missing 
something?

 -3T -MPRAGE -hires

Do we need an expert file with version 7.1 to specify the number of iterations 
for surface inflation or is this now done automatically?

Thank you
Trisanna

________________________________
The materials in this message are private and may contain Protected Healthcare 
Information or other information of a sensitive nature. If you are not the 
intended recipient, be advised that any unauthorized use, disclosure, copying 
or the taking of any action in reliance on the contents of this information is 
strictly prohibited. If you have received this email in error, please 
immediately notify the sender via telephone or return mail.
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to