External Email - Use Caution        

Hello all,

We are working on calculating the volume of thalamic nuclei in our
participants and noticed that there is often a discrepancy in measured
volume in the ThalamicNuclei.v12.T1.volumes.txt and the volume calculated
for the same thalamic nucleus using fslstats -V. (Note that the nuclei are
all created in FreeSurfer, just extracted to individual .nii files
afterwards).

For example: in one control subject, the volume of the right VPL was
measured in FreeSurfer as 264.650938 mm^3, but the same extracted label in
fslstats shows a volume of 242 mm^3. What could be causing this discrepancy?

Thanks

Corinna
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to