Can you send your paradigm files? Can you also send the terminal output? One more thing, can you send the X.mat file from the output folder?
On 1/2/2020 3:19 AM, Marco Ninghetto wrote: External Email - Use Caution Hello experts, I'm performing retinotopy analysis but when running the command selxavg3-sess It starts, but after some lines, I get the following error: ERROR: design is ill-conditioned I don't know how to proceed from here to solve the error. My retinotopy stimuli make 2 cycles (e.g.: rotating wedge makes 2 full cycles before quit) and each cycle takes 200 seconds to complete. TR is set to 2.5 seconds. Please, does anyone have any advice? Thanks in advance, Marco -- --------------------------------------------------- Marco Ninghetto, PhD candidate Laboratory of Neuroplasticity Nencki Institute of Experimental Biology Polish Academy of Sciences 3 Pasteur Street, 02-093 Warsaw, Poland _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu<mailto:Freesurfer@nmr.mgh.harvard.edu> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer