Hello,

I am attempting to combine my motion correction and b0 unwarping steps. I
have .lta files produced by registering every volume of a BOLD run to the
first volume using mri_robust_register and a vsmap for dewarping produced
by epidewarp.fsl. Is it sufficient to input them both into mri_vol2vol to
combine these steps? Something like:  The command I was thinking of trying
was:
mri_vol2vol --mov inFile --targ dstFile --o outFile --lta ltafile --vsm
vsmap --cubic

Or would something about the creation of the .lta files also need to be
changed?

Thanks,

Nathan