Hi,

I'm using freesurfer-Darwin-lion-stable-pub-v5.3.0 and the latest version
of tracula (downloaded Sept 2014). I was running 'trac-all -prior -c
mydmrircfile.txt' with reinit=1 on a few tracts that initially
reconstructed to look like single voxels. The log file indicated there was
difficulty converging on a solution:

INFO: Distances between consecutive points are 12 12 13 14
INFO: Selected control points in test subject's space are
 161 100 154
 163 104 142
 159 105 130
 159 101 117
 160 91 107
INFO: Distances between consecutive points in test subject's space are 13
13 14 14
WARN: Could not find satisfactory control point fit - try 1435
Finding center streamline
INFO: Step is 3 voxels
WARN: Turning off deviation check for center streamline
INFO: Step is 3 voxels
WARN: Turning off FA check for center streamline
INFO: Step is 3 voxels
WARN: Turning off overlap check for center streamline
INFO: Step is 3 voxels
WARN: Turning off overlap check for center streamline


The rest of the 50 GB file is the same last 2 Info and Warn lines. I was
also sending the terminal output to a log file. So, it too contains 50GB of
Info and Warn lines. It wasn't a very large hard drive to start with, but
this did end up leaving the drive with 0 bytes of free space, which also
caused the processes trying to write to the disk at the time to eventually
crash (after reporting there is "no space left on device", many times).

The tracts in question probably won't reconstruct well. But if you have
time for a feature request, maybe you could detect that it hasn't or won't
converge at this point?

Thanks,
Peggy
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

Reply via email to