Hi Anthony and Doug

have you tried control points? If you upload a subject dir I'll take a look

cheers
Bruce


On Mon, 5 Jan 2015, Anthony Dick wrote:

We have the same problem using the same coil (GE 750; mainly occipital
pole), so any suggestions for how to correct this would be very helpful.
Thanks!

Anthony

On 1/5/15, 7:05 PM, Douglas Merkitch wrote:
      Hello Freesurfer experts,
We have T1 data from a 3T GE 32-channel head coil that exhibits areas
of hyperintense white matter. Specifically there are areas of the
wm.mgz on the periphery with values ranging from 117-121, which lead
to overextending/overestimation of the wm.mgz. 

1) Can anyone suggest specific processing options or flags to help
correct for peripheral hyperintense white matter?

2) Can anyone suggest methods of correcting for local overestimation
of white matter on the periphery?

Your help is greatly appreciated!

Doug

Doug Merkitch
Neurological Sciences
Rush University Medical Center






_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mai
l
contains patient information, please contact the Partners Compliance HelpLin
e at
http://www.partners.org/complianceline . If the e-mail was sent to you in er
ror
but does not contain patient information, please contact the sender and prop
erly
dispose of the e-mail.


_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

Reply via email to