Hello, I am running reg-feat2anat and facing some problems.
First I ran the command in its default mode using FSL initialisation reg-feat2anat --feat featdir.feat --subject s. That gave me a bad registration. There is a warning coming up WARNING: initial G-W contrast is negative, but expecting positive. If the mov data has a T1 contrast, re-run with --T1 Next I tried the command using -spm option. The within-subject registration (anat2exf) looks good, but the registration to the standard does not look that good, although not as bad as with -fsl option. The structural and the functional are using different conventions (structural is in radiological convention, whereas functional is neurological). I presume the determinants are associated with this and they have opposite signs. The orientations are also different. Additionally in both the log files (one with -fsl option and -spm option), I get another warning WARNING:: Flipping Left/Right orientation (as det < 0). Not sure whether this warning is something I should worry about. Much appreciate your help. Many thanks, Mariam.
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.