Dear Doug,

I am trying to analyze fMRI data where TR = 1.2 secs. For several subjects
the analysis works as expected, but for about half of the subjects when I
try to execute the command selxavg3-sess terminates with the following
error:

"OLS Beta Pass
  run 1    t= 0.0


ERROR: TR mismatch between analysis and data
analysis TR = 1.2, data TR = 1.56"

I checked the *nii header information and all indicate TR = 1.2 sec. I am
not sure why I get the error. Please advise.

Thanks!

Wishes,

Tapsya


FS-FAST version: 5.2
Machine: adapt
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer