Dear Doug, I am trying to analyze fMRI data where TR = 1.2 secs. For several subjects the analysis works as expected, but for about half of the subjects when I try to execute the command selxavg3-sess terminates with the following error:
"OLS Beta Pass run 1 t= 0.0 ERROR: TR mismatch between analysis and data analysis TR = 1.2, data TR = 1.56" I checked the *nii header information and all indicate TR = 1.2 sec. I am not sure why I get the error. Please advise. Thanks! Wishes, Tapsya FS-FAST version: 5.2 Machine: adapt _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.