Dear Douglas, I don't use image compression. The series are new to me, I see that the images uses a multiframe encoding, there is 63 directions each direction encoded in a sigle image like a BOLD EPI sequence
I will check again all the series Thanks for the reply John Ochoa Universidad de Antioquia On Wed, Feb 22, 2012 at 1:36 PM, Douglas N Greve <gr...@nmr.mgh.harvard.edu>wrote: > It sounds like something went wrong with the conversion to nifti. Do you > use image compression? Are you sure that the series is the correct one? > doug > > John Fredy wrote: > >> Hello all, >> >> I am trying to use a set of dti data from a Magnetom Skyra 3T. I use the >> dt_recon process with data from another siemens of 1.5T without problems. >> With the Skyra 3T I have the following error in the log file: >> >> MRIresample(): error inverting matrix; determinant is nan, matrix is: >> >> Can someone help me with this problem? >> >> Thanks in advance >> >> John Ochoa >> Universidad de Antioquia >> ------------------------------**------------------------------** >> ------------ >> >> ______________________________**_________________ >> Freesurfer mailing list >> Freesurfer@nmr.mgh.harvard.edu >> https://mail.nmr.mgh.harvard.**edu/mailman/listinfo/**freesurfer<https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer> >> > > -- > Douglas N. Greve, Ph.D. > MGH-NMR Center > gr...@nmr.mgh.harvard.edu > Phone Number: 617-724-2358 Fax: 617-726-7422 > > Bugs: > surfer.nmr.mgh.harvard.edu/**fswiki/BugReporting<http://surfer.nmr.mgh.harvard.edu/fswiki/BugReporting> > FileDrop: > www.nmr.mgh.harvard.edu/**facility/filedrop/index.html<http://www.nmr.mgh.harvard.edu/facility/filedrop/index.html> > > > > The information in this e-mail is intended only for the person to whom it > is > addressed. If you believe this e-mail was sent to you in error and the > e-mail > contains patient information, please contact the Partners Compliance > HelpLine at > http://www.partners.org/**complianceline<http://www.partners.org/complianceline>. > If the e-mail was sent to you in error > but does not contain patient information, please contact the sender and > properly > dispose of the e-mail. > >
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.