Hi Allison,
Thank you very much for your help! I am using v5.0.0.
Is the surface of the white-matter (from the surface-based stream) used here to 
calculate the volume in CorticalWhiteMatterVol and is this why I have 
sub-millimeter values here?
This value is in fact different from the value that can be calculated in 
mri_segstats for cerebral-white-matter using the command "mri_segstats --seg 
aseg.mgz --ctab $FREESURFER_HOME/FreeSurferColorLUT.txt --sum test1.stats". Is 
this because segstats makes the calculation here in voxels? Is it therefore 
better to take the value from CorticalWhiteMatterVol which would take the 
white-matter surface into account?
Best,
Ruthger



________________________________________
From: Allison Stevens [astev...@nmr.mgh.harvard.edu]
Sent: Friday, May 20, 2011 2:56 PM
To: Righart, Ruthger  Dr.
Cc: freesurfer@nmr.mgh.harvard.edu
Subject: Re: [Freesurfer] What is the difference between Cerebral-white-matter 
and Cortical-white-matter in Freesurfer?

Which version of FreeSurfer are you using? In the more recent versions, they 
are the same. Cortical White Matter is all the white matter contained within 
the white surface minus the subcortical gray matter and ventricles, etc.

On May 20, 2011, at 7:37 AM, "Righart, Ruthger  Dr." 
<ruthger.righ...@med.uni-muenchen.de> wrote:

> Dear All,
>
> I am working with the volume-based stream in Freesurfer and I have a question 
> about what is the difference between the volumes given for 
> Cortical-white-matter and Cerebral-white-matter? How are the volumes 
> calculated for both in Freesurfer? Is it the difference of including or not 
> including the subcortical gray matter and ventricles in the calculation?
>
> I have read previous mailings ( e.g. 
> http://www.mail-archive.com/freesurfer@nmr.mgh.harvard.edu/msg15449.html ) 
> but I am still confused what is the difference between these measures.
>
> Thank you very much in advance for your help!
>
> Ruthger Righart (PhD)
>
> Institute for Stroke and Dementia Research (ISD)
> Klinikum der Universität München
> Max-Lebsche-Platz 30
> 81377 Munich | Germany
>
> ruthger.righ...@med.uni-muenchen.de
>
>
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
>
>


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to