Hi Doug, Is --reorder4 a new feature in one of the more recent releases? (Currently, I'm using mri_convert from v4.1.0, and I don't see a -- reorder4 flag).
Also, can you please clarify what do you mean when you said that -- out_orientation should not resample? If I take an nii file with this transform: Orientation : PSR Primary Slice Direction: sagittal voxel to ras transform: -0.0229 -0.0300 1.1991 -88.7736 -0.9978 0.0634 -0.0251 144.1823 0.0628 0.9975 0.0377 -139.2478 0.0000 0.0000 0.0000 1.0000 and run it through "mri_convert --out_orientation LAS input.nii output.nii", then mri_convert spits out the following: Setting output orientation to LAS Reslicing using trilinear interpolation And the output.nii has this transform: Orientation : LAS Primary Slice Direction: axial voxel to ras transform: -1.0000 0.0000 0.0000 120.5695 0.0000 1.0000 0.0000 -97.4406 0.0000 -0.0000 1.2000 -97.0175 0.0000 0.0000 0.0000 1.0000 That is, both the "Reslicing using trilinear interpolation" comment and the xforms themselves appear to indicate that resampling was performed. thanks for clarifying, -MH On Fri, 2010-02-05 at 14:03 -0500, Douglas N Greve wrote: > Sorry, I don't have anything that will reorder and change the geometry > to be correct. You might be able to do it with --reorder4 (and not > --reorder) in combination with --out_orientation. --out_orientation > should not resample. > > doug > > Michael Harms wrote: > > Hello Doug, > > Is it possible using mri_convert to just reorder the way in which the > > data is stored, without any resampling of the actual voxel values? > > > > i.e., I have Siemen's MPRAGE DICOMs, and if run mri_convert, I get a > > default "PIL" orientation. I would like to just reorder the way in > > which the data is stored, to get a "LAS" orientation instead. > > > > I tried using "--out_orientation LAS", but that does a resampling > > (interpolation) such that the resulting xform has strictly 0's on the > > off-diagonal. And reading the mri_convert help, it clearly states that > > the --out_orientation flag is to be used when the input orientation is > > WRONG, which is not the case here (since I presume that the input > > orientation is correctly read out of the DICOMs). > > > > I tried "--reorder 2 1 3", to see what effect that has on a file already > > in nii format, but I got the message: in nii format, but I got the > > message: > > reordering axes... > > MRIreorder: incorrect dst width > > error reordering axes > > > > I've checked the archives, and read through the mri_convert help, but > > just can't seem to figure out if reordering from one orientation to > > another (without resampling) is possible using mri_convert. > > > > thanks, > > -MH > > > > > > > _______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer