Hi Doug,

Is --reorder4 a new feature in one of the more recent releases?
(Currently, I'm using mri_convert from v4.1.0, and I don't see a --
reorder4 flag).

Also, can you please clarify what do you mean when you said that --
out_orientation should not resample?

If I take an nii file with this transform:

Orientation   : PSR
Primary Slice Direction: sagittal
voxel to ras transform:
               -0.0229  -0.0300   1.1991   -88.7736
               -0.9978   0.0634  -0.0251   144.1823
                0.0628   0.9975   0.0377  -139.2478
                0.0000   0.0000   0.0000     1.0000

and run it through "mri_convert --out_orientation LAS input.nii
output.nii", then mri_convert spits out the following:

Setting output orientation to LAS
Reslicing using trilinear interpolation

And the output.nii has this transform:

Orientation   : LAS
Primary Slice Direction: axial

voxel to ras transform:
               -1.0000   0.0000   0.0000   120.5695
                0.0000   1.0000   0.0000   -97.4406
                0.0000  -0.0000   1.2000   -97.0175
                0.0000   0.0000   0.0000     1.0000

That is, both the "Reslicing using trilinear interpolation" comment and
the xforms themselves appear to indicate that resampling was performed.

thanks for clarifying,
-MH


On Fri, 2010-02-05 at 14:03 -0500, Douglas N Greve wrote:
> Sorry, I don't have anything that will reorder and change the geometry 
> to be correct. You might be able to do it with --reorder4 (and not 
> --reorder) in combination with --out_orientation. --out_orientation 
> should not resample.
> 
> doug
> 
> Michael Harms wrote:
> > Hello Doug,
> > Is it possible using mri_convert to just reorder the way in which the
> > data is stored, without any resampling of the actual voxel values?
> >
> > i.e., I have Siemen's MPRAGE DICOMs, and if run mri_convert, I get a
> > default "PIL" orientation.  I would like to just reorder the way in
> > which the data is stored, to get a "LAS" orientation instead.
> >
> > I tried using "--out_orientation LAS", but that does a resampling
> > (interpolation) such that the resulting xform has strictly 0's on the
> > off-diagonal.  And reading the mri_convert help, it clearly states that
> > the --out_orientation flag is to be used when the input orientation is
> > WRONG, which is not the case here (since I presume that the input
> > orientation is correctly read out of the DICOMs).
> >
> > I tried "--reorder 2 1 3", to see what effect that has on a file already
> > in nii format, but I got the message: in nii format, but I got the
> > message:
> > reordering axes...
> > MRIreorder: incorrect dst width
> > error reordering axes
> >
> > I've checked the archives, and read through the mri_convert help, but
> > just can't seem to figure out if reordering from one orientation to
> > another (without resampling) is possible using mri_convert.
> >
> > thanks,
> > -MH
> >
> >  
> >   
> 

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to