Hi,
I've been using the matlab scripts to load and save mgh files. I've
noticed a difference in the precision in my original volumes and the ones
I've saved with matlab. Namely, after saving a volume with matlab and
loading it up in tkmedit I notice that everything now has an extra 2
digits of precision (aka. voxels with an intensity of 100 now have an
intensity of 100.00).

Is there any way to remedy this small problem? I've used an integer array
in matlab, and I've tried to just mri_convert the volume in hopes that it
would truncate the values.

I'm only asking because cor2label won't work with the matlab saved
volumes. Any help is appreciated. Thanks!

~Jed


_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer