I have nearly identical setups, but ix0 and ix1 are getting different
options at boot. This seems to be the only difference I see between
machines and I am trying to answer the question, Why can Server A iperf
close to line rate while the other servers can not?
The Test: iperf -P 3 -c REMOTE_ADDR
Server A (ix1) -> Server C (ix0) = 9.4Gbps
Server B (ix0)-> Server C (ix0) = 5.6Gbps
Server C (ix0)-> A (ix1) or B (ix0) = 5.0Gbps
The motherboards are identical between A,B and C and the configs very
similar. The only difference is that Server A is plugged into ix1 while
Server B and C are using ix0.
I am not modifying the flags at boot (eg ifconfig -tso), yet ix0 lacks
TXCSUM,TSO4,TSO6,LRO,WOL.
ix0: flags=8943<UP,BROADCAST,RUNNING,PROMISC,SIMPLEX,MULTICAST> metric 0
mtu 1500
options=a538b9<RXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,VLAN_HWCSUM,WOL_UCAST,WOL_MCAST,WOL_MAGIC,VLAN_HWFILTER,VLAN_HWTSO,RXCSUM_IPV6>
ether *ac:1f:6b:6a:14:6*4
media: Ethernet autoselect (10Gbase-T <full-duplex>)
ix1: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500
options=e53fbb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,VLAN_HWCSUM,TSO4,TSO6,LRO,WOL_UCAST,WOL_MCAST,WOL_MAGIC,VLAN_HWFILTER,VLAN_HWTSO,RXCSUM_IPV6,TXCSUM_IPV6>
ether *ac:1f:6b:6a:14:6*5
media: Ethernet autoselect (10Gbase-T <full-duplex>)
I did try adding some flags to ix0 and -- not sure if this was the
reason -- the box started acting oddly and I ended up rebooting it.
My hunch has is that there is somethign with the TSO4.
Rudy
_______________________________________________
freebsd-net@freebsd.org mailing list
https://lists.freebsd.org/mailman/listinfo/freebsd-net
To unsubscribe, send any mail to "freebsd-net-unsubscr...@freebsd.org"