Well none of the suggestions about star grounding did any good. In fact 
they made the problem worse than before, so bad I could not even get 2.6 
to run. Off this list I was sent the AB servo best wiring practices pdf 
which explained how to reduce noise in a servo drive enclosure. I 
followed the advise as much as possible and after removing all my ground 
wire antennas I was back running with an occasional sserial error. The 
short explanation is to terminate the shields to a ground plane as close 
as possible to the point where you take the shield/drain wire from the 
cable. I still have a cable bundle running to my switch box that is 
parallel wires and I might replace that with some twisted pairs. Photos 
at 11.

JT

------------------------------------------------------------------------------