On 18 February 2011 18:44, Doug <[email protected]> wrote: > I tried without the Estop line and yes the hal connects the estop-out. And > yes I toggled the estop. I am not sure how fast the frequency would be but > a volt meter does not show anything. My PBMX board with charge pump do not > enable because it does not sense anything on pin 17.
It ought to be working then. In the Machine -> Show HAL Config -> Watch window can you see the charge-pump.enable pin toggle with estop? Can you see the charge-pump function in the base thread (I think that is visible in the same window, under "Functions", otherwise you can type "halcmd show function" in a command line window while EMC2 is running. Also check that the base thread time is not zero, and that the p-port pin and charge-pump are shown as linked. In fact, please put the main HAL and custom HAL files on www.pastebin.com where we can have a proper look at them. (You might as well paste the output of dmesg there too.) -- atp "Torque wrenches are for the obedience of fools and the guidance of wise men" ------------------------------------------------------------------------------ The ultimate all-in-one performance toolkit: Intel(R) Parallel Studio XE: Pinpoint memory and threading errors before they happen. Find and fix more than 250 security defects in the development cycle. Locate bottlenecks in serial and parallel code that limit performance. http://p.sf.net/sfu/intel-dev2devfeb _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users