Thanks for your responses. Sent from my T-Mobile 5G Device -------- Original message --------From: Steve Brody <[email protected]> Date: 4/6/23 4:41 PM (GMT-05:00) To: PSES List Server <[email protected]> Subject: Multiple electrical power sources A new question. A client's product is using two independent AC power sources on a product, but I can't find anything in 61010-1 60204-1 that provide any guidance on compliance. The obvious is that the sections of the product that are fed from source A or B are not interrelated in any way that would create a hazard for for the other section, that there be a warning label adjacent to each input that says there are multiple AC sources, and that each section has it's own circuit protection and disconnect, even if a facility disconnect is used for both. What am I missing? Thanks, Steve Brody [email protected] C - 603 617 9116
- ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]> _________________________________________________ To unsubscribe from the EMC-PSTC list, click the following link: https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1