You might want to take a look at UL/IEC/EN 60950-1 which I know definitely has 
requirements for multiple power sources.  62368 may have guidance as well

Get Outlook for iOS<https://aka.ms/o0ukef>
________________________________
From: Richard Nute <[email protected]>
Sent: Thursday, April 6, 2023 8:15:02 PM
To: [email protected] <[email protected]>
Subject: Re: [PSES] Multiple electrical power sources






Hi Steve:



The TV broadcast industry electronic products have used two (redundant) AC 
sources for their products for many years.  You may have some help there.



Rich





From: Steve Brody <[email protected]>
Sent: Thursday, April 6, 2023 1:42 PM
To: [email protected]
Subject: [PSES] Multiple electrical power sources



A new question.



A client's product is using two independent AC power sources on a product, but 
I can't find anything in 61010-1 60204-1 that provide any guidance on 
compliance.



The obvious is that the sections of the product that are fed from source A or B 
are not interrelated in any way that would create a hazard for for the other 
section, that there be a warning label adjacent to each input that says there 
are multiple AC sources, and that each section has it's own circuit protection 
and disconnect, even if a facility disconnect is used for both.



What am I missing?



Thanks,





Steve Brody

[email protected]<mailto:[email protected]>

C - 603 617 9116



-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]<mailto:[email protected]>>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html

Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to 
unsubscribe)<http://www.ieee-pses.org/list.html>
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell <[email protected]<mailto:[email protected]>>

For policy questions, send mail to:
Jim Bacher <[email protected]<mailto:[email protected]>>
David Heald <[email protected]<mailto:[email protected]>>

________________________________

To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>
_________________________________________________
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1

Reply via email to