Dear Listing Members

Dear CE Marking Association

We are currently carrying out an EMC Directive assessment of one of our Vehicle 
Mounted Military Systems against the Generic EMC Standards for Industrial 
Environments. It is a dc powered standalone Military System with no external 
Signal Port Input or Output connections. It does have one external DC Input 
Port whose sole purpose is for charging the system batteries when the system is 
not in service. The length of the system battery charging cable is < 3m. In 
normal operation this external DC Input Port is not used.

The Vehicle Mounted Military System consists of a number of sub-systems 
connected via fully screened interconnection cabling some of which are longer 
than 3 metres but all are much less than 30 metres long. The interconnection 
cabling is in some cases a combination of both signal and dc power connections 
but there are also some solely signal cables and dc power cables as well.

My question relates to whether the EN 61000-6-2 Signal and DC Power Ports 
Radio-Frequency Common Mode test requirements are applicable to the sub-system 
interconnection cabling whose length is greater than 3m or not? Noting as 
previously stated the system has no external cable connections in normal 
operation.

I am aware that DC Power connections do not have any cable length exemptions 
but in a standalone system this would not be considered to be a “DC 
Distribution Network”.

Your advice on this matter would be greatly appreciated.



Regards

Philip Stevenson



Sent from Mail<https://go.microsoft.com/fwlink/?LinkId=550986> for Windows 10


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to