> On Mar 19, 2009, at 1:26 PM, Chris Randle wrote:

>> I've noticed that, when working in the new frame, changing the TODO
>> state of any item within the frame to DONE (when it is the currently
>> clocked in item) does not stop the clock. Going back to my main frame
>> and doing the same thing there on the same item does stop the clock.

Carsten Dominik <domi...@science.uva.nl> writes:

> I am no able to reproduce this.  Can anyone else try, please?
>
> - Carsten

I just tested it (with org from the git repo). The problem seems to
occur when a clock is started on an item before the indirect buffer is
created. In other words, the clock did not stop when I followed these
steps:

   1. Clocked into an item.

   2. Created an indirect buffer.

   3. Clocked out within the indirect buffer.

The clock did stop when I *both* clocked in and out within the indirect
buffer.

- Matt




_______________________________________________
Emacs-orgmode mailing list
Remember: use `Reply All' to send replies to the list.
Emacs-orgmode@gnu.org
http://lists.gnu.org/mailman/listinfo/emacs-orgmode

Reply via email to