Hi everyone,

Russell, Would HA manager also manage ovn-controller switch over?


Yes, indirectly.  The way this is typically handled is by using a virtual
IP that moves to whatever host is currently the master

Cool, then ovn-controller does not have to be HA aware.

In my understanding, the virtual IP feature in Pacemaker (i.e. IPaddr2) works if both active and passive nodes of the cluster are in the same IP subnet.

For some deployments, this would mean both nodes a located on the same physical rack. This is not actually a fault-tolerant design (think blackout).

If I'm getting virtual IP addresses in Pacemaker correct, wouldn't it be better to make ovn-controller HA aware? That is, have a node switching command (akin to ovsdb-server/connect-active-ovsdb-server) and let Pacemaker make use it?

If this sounds reasonable, I can take on it probably.
If not, I'd greatly appreciate if someone could explain me what I'm missing.

--
Thanks,
Valentine Sinitsyn