On Sat, Jun 28, 2014 at 08:59:01AM -0700, Jesse Gross wrote: > On Fri, Jun 27, 2014 at 5:55 PM, Simon Horman <ho...@verge.net.au> wrote: > > On Wed, Jun 25, 2014 at 10:51:52AM +0900, Simon Horman wrote: > >> On Tue, Jun 24, 2014 at 04:24:37PM -0700, Jesse Gross wrote: > >> > * Maybe you can refresh my memory - in the case of a push_mpls after > >> > pop_vlan, why can't we do this check correctly for at least one level > >> > of vlan? It seems like we could use the inner EtherType to tell > >> > whether an additional vlan tag is present. > >> > >> That seems likely. I'll do some analysis and get back to you. > > > > I may be missing something but it seems to me that in > > ovs_nla_copy_actions__() we have access to the outer EtherType and > > VLAN TCI but not the inner EtherType. > > > > It seems to me that the inner EtherType would need to be present > > in the key for it to be available in ovs_nla_copy_actions__(). > > The inner EtherType (first level) is actually what is stored in > eth.type in the flow. When eth.tci is set it is assumed that the outer > EtherType is 0x8100 and that isn't stored.
Yes, of course. Sorry for missing that. _______________________________________________ dev mailing list dev@openvswitch.org http://openvswitch.org/mailman/listinfo/dev