> Please add Jacob to AUTHORS.
>
> This adds an odd blank line near the end of cfm_run().

Done.


> The current message reports missing sequence numbers, but I think that
> there are at least two other possible issues: duplicate sequence
> numbers and out-of-order sequence numbers.  It might be a good idea
> either to detect and report these with separate messages (based on
> whether the new sequence number is greater than, less than, or equal
> to the previous number), or to make the single message make a less
> specific claim about the problem.

I changed the warning message to the following.  I'd prefer to avoid
trying to guess the exact reason for the sequence number anomalies.

+                VLOG_WARN_RL(&rl, "%s: (mpid %"PRIu64") detected sequence"
+                             " numbers which indicate possible connectivity"
+                             " problems (previous %"PRIu32") (current %"PRIu32
+                             ")", cfm->name, ccm_mpid, rmp->seq, ccm_seq);

Ethan
_______________________________________________
dev mailing list
dev@openvswitch.org
http://openvswitch.org/mailman/listinfo/dev

Reply via email to