Hi Ferruh,

On Mon, Mar 27, 2017 at 04:08:51PM +0100, Ferruh Yigit wrote:
On 3/3/2017 3:40 PM, Gaetan Rivet wrote:
Most ConnectX-3 adapters expose two physical ports on a single PCI bus
address.

Add a new port parameter allowing the user to choose
either or both physical ports to be used by the application.

This parameter is used as follows:

Selecting only the second port:
   -w 00:00.0,port=1

Selecting both ports:
   -w 00:00.0,port=0,port=1

If no parameter is given, the default behavior is unchanged: all ports
are probed.

Signed-off-by: Gaetan Rivet <gaetan.ri...@6wind.com>

Hi Gaetan,

Getting following checkpatch warning [1], can you please address it?


Sure, here it is: http://dpdk.org/ml/archives/dev/2017-March/061582.html

Sorry for that, I was checking it with an older checkpatch.pl.

Thanks,
ferruh

[1]
WARNING:UNSPECIFIED_INT: Prefer 'unsigned int' to bare use of 'unsigned'
#156: FILE: drivers/net/mlx4/mlx4.c:5462:
+       unsigned arg_count;

--
Gaëtan Rivet
6WIND

Reply via email to