On 3/16/2017 11:04 AM, Adrien Mazarguil wrote: > On Fri, Mar 03, 2017 at 04:40:06PM +0100, Gaetan Rivet wrote: >> Most ConnectX-3 adapters expose two physical ports on a single PCI bus >> address. >> >> Add a new port parameter allowing the user to choose >> either or both physical ports to be used by the application. >> >> This parameter is used as follows: >> >> Selecting only the second port: >> -w 00:00.0,port=1 >> >> Selecting both ports: >> -w 00:00.0,port=0,port=1 >> >> If no parameter is given, the default behavior is unchanged: all ports >> are probed. >> >> Signed-off-by: Gaetan Rivet <gaetan.ri...@6wind.com> > > I think this patch is good as is. Whatever value results from users > specifying random characters as argument to the port parameter is their > problem, as long as the resulting value is verified to be within bounds, > it's fine. > > I'm not saying that checking all possible failure modes of strtoul() is > useless, just that it seems overkill in this specific case. Using atoi() > without any error checking would have been perfectly fine as well. > > Acked-by: Adrien Mazarguil <adrien.mazarg...@6wind.com>
Hi Adrien, Gaetan, Are all comments addressed for this patch? It looks like discussion is going on? Thanks, ferruh