Hello Ferruh,


I have two more clarification requests, can you please check them below?


If one ore more flow failed to update, for any reason, should user retry
the update (in that case we need a retry error maybe) and can user still
call 'rte_flow_template_table_resize_complete()' (for possible next
table resize operation)? Can you please clarify this in your document.

Please see my comment below.


When user calls update() with a flow from new table, API should ignore
it and return success, you mentioned this is what mlx implementation is
doing, what do you think to make this as default API behavior and
document it in above API documentation?



I'll update the patch.


If 'rte_flow_template_table_resize_complete()' fails, can application
call another resize()? Is this managed in the application level or
driver level (by returning error to next resize if complete() is not
successful)? Is it something to clarify in your document?



PMD failures in `rte_flow_async_update_resized()` and `rte_flow_template_table_resize_complete()` are not recoverable.