> -----Original Message-----
> From: Ferruh Yigit <ferruh.yi...@amd.com>
> Sent: Saturday, November 19, 2022 2:26 AM
> To: Hanumanth Reddy Pothula <hpoth...@marvell.com>;
> tho...@monjalon.net; andrew.rybche...@oktetlabs.ru; Nithin Kumar
> Dabilpuram <ndabilpu...@marvell.com>
> Cc: dev@dpdk.org; yux.ji...@intel.com; Jerin Jacob Kollanukkaran
> <jer...@marvell.com>; Aman Singh <aman.deep.si...@intel.com>; Yuying
> Zhang <yuying.zh...@intel.com>
> Subject: [EXT] Re: [PATCH v4 1/1] app/testpmd: add valid check to verify
> multi mempool feature
> 
> External Email
> 
> ----------------------------------------------------------------------
> On 11/18/2022 2:13 PM, Hanumanth Pothula wrote:
> > Validate ethdev parameter 'max_rx_mempools' to know whether device
> > supports multi-mempool feature or not.
> >
> 
> My preference would be revert the testpmd patch [1] that adds this new
> feature after -rc2, and add it back next release with new testpmd argument
> and below mentioned changes in setup function.
> 
> @Andrew, @Thomas, @Jerin, what do you think?
> 
> 
> [1]
> 4f04edcda769 ("app/testpmd: support multiple mbuf pools per Rx queue")
> 
> > Bugzilla ID: 1128
> >
> 
> Can you please add fixes line?
> 
Ack
> > Signed-off-by: Hanumanth Pothula <hpoth...@marvell.com>
> 
> Please put the changelog after '---', which than git will take it as note.
> 
Ack
> > v4:
> >  - updated if condition.
> > v3:
> >  - Simplified conditional check.
> >  - Corrected spell, whether.
> > v2:
> >  - Rebased on tip of next-net/main.
> > ---
> >  app/test-pmd/testpmd.c | 10 ++++++++--
> >  1 file changed, 8 insertions(+), 2 deletions(-)
> >
> > diff --git a/app/test-pmd/testpmd.c b/app/test-pmd/testpmd.c index
> > 4e25f77c6a..c1b4dbd716 100644
> > --- a/app/test-pmd/testpmd.c
> > +++ b/app/test-pmd/testpmd.c
> > @@ -2655,17 +2655,23 @@ rx_queue_setup(uint16_t port_id, uint16_t
> rx_queue_id,
> >     union rte_eth_rxseg rx_useg[MAX_SEGS_BUFFER_SPLIT] = {};
> >     struct rte_mempool *rx_mempool[MAX_MEMPOOL] = {};
> >     struct rte_mempool *mpx;
> > +   struct rte_eth_dev_info dev_info;
> >     unsigned int i, mp_n;
> >     uint32_t prev_hdrs = 0;
> >     int ret;
> >
> > +   ret = rte_eth_dev_info_get(port_id, &dev_info);
> > +   if (ret != 0)
> > +           return ret;
> > +
> >     /* Verify Rx queue configuration is single pool and segment or
> >      * multiple pool/segment.
> > +    * @see rte_eth_dev_info::max_rx_mempools
> >      * @see rte_eth_rxconf::rx_mempools
> >      * @see rte_eth_rxconf::rx_seg
> >      */
> > -   if (!(mbuf_data_size_n > 1) && !(rx_pkt_nb_segs > 1 ||
> > -       ((rx_conf->offloads & RTE_ETH_RX_OFFLOAD_BUFFER_SPLIT) !=
> 0))) {
> > +   if ((dev_info.max_rx_mempools == 0) && (rx_pkt_nb_segs <= 1 ||
> 
> Using `dev_info.max_rx_mempools` for check means if device supports
> multiple mempool, multiple mempool will be configured independent from
> user configuration. But user may prefer singe mempool or buffer split.
> 
Please find my suggested logic.

> Right now only PMD support multiple mempool is 'cnxk', so this doesn't
> impact others but I think this is not correct.
> 
> Instead of re-using testpmd "mbuf-size" parameter (it is already used for
> two other features, and this is the reason of the defect) it would be better
> to have an explicit parameter for multiple mempool feature.
> 
> 
> > +       ((rx_conf->offloads & RTE_ETH_RX_OFFLOAD_BUFFER_SPLIT) ==
> 0))) {
> >             /* Single pool/segment configuration */
> >             rx_conf->rx_seg = NULL;
> >             rx_conf->rx_nseg = 0;
> 
> 
> Logic seems correct, although I have not tested.
> 
> Current functions tries to detect the requested feature and setup queues
> accordingly, features are:
> - single mempool
> - packet split (to multiple mempool)
> - multiple mempool (various size)
> 
> And the logic in the function is:
> ``
> if ( (! multiple mempool) && (! packet split))
>       setup for single mempool
>       exit
> 
> if (packet split)
>       setup packet split
> else
>       setup multiple mempool
> ``
> 
> What do you think to
> a) simplify logic by making single mempool as fallback and last option,
> instead of detecting non existence of other configs
> b) have explicit check for multiple mempool
> 
> Like:
> 
> ``
> if (packet split)
>       setup packet split
>       exit
> else if (multiple mempool)
>       setup multiple mempool
>       exit
> 
> setup for single mempool
> ``
> 
> I think this both solves the defect and simplifies the code.

Yes Ferruh your suggested logic simplifies the code.

In the lines of your proposed logic,  below if conditions might work fine for 
all features(buffer-split/multi-mempool) supported by PMD and user preference,

if (rx_pkt_nb_segs > 1 ||
            rx_conf->offloads & RTE_ETH_RX_OFFLOAD_BUFFER_SPLIT) {
        /*multi-segment (buffer split)*/
} else if (mbuf_data_size_n > 1 && dev_info.max_rx_mempools > 1) {
        /*multi-mempool*/
} else {
        /* single pool and segment */
} 

Or  adding new Rx offload parameter for multi_mempool feature, I think it might 
not be required, using dev_info.max_rx_mempools works fine.

if (rx_pkt_nb_segs > 1 ||
            rx_conf->offloads & RTE_ETH_RX_OFFLOAD_BUFFER_SPLIT) {
        /*multi-segment (buffer split)*/
} else if (mbuf_data_size_n > 1 && rx_conf->offloads & 
RTE_ETH_RX_OFFLOAD_MULTI_MEMPOOL ) {
        /*multi-mempool*/
} else {
        /* single pool and segment */
}

Please let me know your inputs on above logic.