On Tue, 8 Sep 2020 21:17:50 +0100 Cristian Dumitrescu <cristian.dumitre...@intel.com> wrote:
> +/* > + * Pipeline. > + */ > +struct rte_swx_pipeline { > + int build_done; > + int numa_node; > +}; > + > + Is int the right type for these. build_done seems like a boolean and numa_node should be unsigned?