Hi Harman,

On 05/07/2019 11:05, Harman Kalra wrote:
On restarting worker 0 after shutdown, packets handled by
worker 0 must be incremented only when a packet is received by
it.

Fixes: c3eabff124e6 ("distributor: add unit tests")
Cc: sta...@dpdk.org

Signed-off-by: Harman Kalra <hka...@marvell.com>
---
  app/test/test_distributor.c | 3 ++-
  1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/app/test/test_distributor.c b/app/test/test_distributor.c
index 8084c0794..5d71bf87c 100644
--- a/app/test/test_distributor.c
+++ b/app/test/test_distributor.c
@@ -374,7 +374,8 @@ handle_work_for_shutdown_test(void *arg)
                                id, buf, buf, num);
while (!quit) {
-                       worker_stats[id].handled_packets++, count++;
+                       worker_stats[id].handled_packets += num;
+                       count += num;
                        rte_pktmbuf_free(pkt);
                        num = rte_distributor_get_pkt(d, id, buf, buf, num);
                }


Change makes sense. Builds OK, Runs OK, test passes.

Acked-by: David Hunt <david.h...@intel.com>