On May 27 14:23, Corinna Vinschen wrote: > Hi Takashi, > > On May 21 20:53, Takashi Yano wrote: > > [...] > > + if (output_handle_local) > > + { > > + OBJECT_BASIC_INFORMATION obi; > > + NTSTATUS status; > > + ULONG hdl_cnt = 0; > > + > > + status = NtQueryObject (output_handle_local, ObjectBasicInformation, > > + &obi, sizeof obi, NULL); > > + if (!NT_SUCCESS (status)) > > + debug_printf ("NtQueryObject: %y", status); > > + else > > + hdl_cnt = obi.HandleCount; > > + termios_printf("HandleCount: %d", hdl_cnt); > > + if (hdl_cnt == 1) > > + SetEvent (input_available_event); > > + CloseHandle (output_handle_local); > > + } > > Isn't that racy? Consider two processes doing that at the same time. > Both calls to NtQueryObject could come up with hdl_cnt == 2 and the > problem persists. > > Wouldn't it be safer to call SetEvent(input_available_event) all the > time from here?
We discussed this already in March and only briefly talked about a change like this requiring changes to fhandler_pty_slave::read. However, I don't see this. The read code already takes 0 bytes input and broken pipe scenarios into account. Do you see something needing a change I don't? Thanks, Corinna -- Corinna Vinschen Please, send mails regarding Cygwin to Cygwin Maintainer cygwin AT cygwin DOT com Red Hat