* Steve Holdoway wrote:
> 
> On the clamd side I just get:
> 
> Sat Mar 13 17:48:41 2010 -> ERROR: ScanStream 1138: accept timeout.
> 
> on the milter machine, I get:
> 
> Sat Mar 13 17:48:41 2010 -> Failed to establish a connection to clamd
> Sat Mar 13 17:48:41 2010 -> ERROR: Failed to communicate with clamd for
> streaming
> Sat Mar 13 17:48:41 2010 -> ERROR: Failed to initiate
> streaming/fdpassing
> 
> Can anyone point me to where I should be looking ( conf file entries,
> etc )??? All I've changed is 
> 
>   CommandReadTimeout 30
> 

I get those errors with these clamd settings

CommandReadTimeout 120
ReadTimeout 900

This is with the milter load balancing across 5 nodes.

Cheap, Fast, & Right, pick two.

Obviously, fast didn't get on the list.

-- 
Sincerely,

Nathan Gibbs