Hi,

I thought the "fail" needs to propagated as well. Am I false?

Who can have a look if  a markdown message in "fast shutdown" mode is a
possibilitiy? I do not have the expertice to say if this would breakt
something else. But if this is possible I would vote for this.


Thanks
Manuel

On Fri, 14 Aug 2020 14:02:30 +0200
Dan van der Ster <d...@vanderster.com> wrote:

> Hi,
> 
> I suppose the idea is that it's quicker to fail via the connection
> refused setting than by waiting for an osdmap to be propagated across
> the cluster.
> 
> It looks simple enough in OSD.cc to also send the down message to the
> mon even with fast shutdown enabled. But I don't have any clue if that
> would cause other issues.
> 
> -- Dan
> 
> 
> 
_______________________________________________
ceph-users mailing list -- ceph-users@ceph.io
To unsubscribe send an email to ceph-users-le...@ceph.io

Reply via email to