On 3/10/23 17:42, Paul Koning via cctalk wrote:

> CDC 6000 series is the one I know of.  But they'd also use either 1 or 3 
> phase regular 50/60 Hz power.  For example, the console display uses 3 phase 
> 400 Hz for its power supplies (nice for low ripple) and 60 Hz 110 V for fans. 
>  The CPU cabinet takes 400 Hz power to run its power supplies but 60 Hz power 
> for the compressors that cool the Freon that cools the logic.

I believe some of the tape drives used 208V 60Hz single-phase.   I'm
pretty sure the big disk drives (e.g. 808) had 3-phase spindle motors
powered from the 240V feed.  I'd have to check, however.  400Hz for the
logic.  I don't recall what the Bryant 4000 drives used, but I"m sure
that bitsavers can tell you.

--Chuck