A few months ago, thanks to help from several people here, I converted an SQ703 TMSCP controller to SQ706 MSCP.
I had problems trying to use it on the vax due to the complexity of mapping Q-Bus registers under ODT, so put off trying until I got the LSI-11/73 going. Now I have a problem: It seems to run and recognise the controller as SQ706 according to the on-board diagnostics, however it insists saying it is at 777450, the TMSCP address. Trying to change it gives me an out-of-bounds message. OK, I thought, I will just use it there. Put it in to a running RT11 system and it shows up at 772150 and clashes with an existing controller! It seems that one of the PALs is maybe setting up the address! Anybody else tried this? cheers, Nigel Here's the fun: https://www(dot)bbc(dot)com/news/entertainment-arts-59089596 Maybe our vax computers will become popular once again! -- Nigel Johnson, MSc., MIEEE, MCSE VE3ID/G4AJQ/VA3MCU Amateur Radio, the origin of the open-source concept! Skype: TILBURY2591 nw.john...@ieee.org