On 8/13/20 9:58 PM, dwight via cctalk wrote: > How much current is ir suppose to carry? I'd just replace it with a piece of > wire wrap wire if it is less than an amp. > Of course, I assume you've fixed what ever failed to cause it to blow. > Gold wire is expensive. > Dwight
According to my tables, AWG 30 copper wire has a resistance of 0.107 ohm per foot or about 9 milliohm per inch. I suspect that it would work under almost all PCB repair conditions. I've repaired power traces on CPU boards using WW wire with no ill effects. --Chuck