On Sat, Jan 27, 2018 at 2:02 PM, Ethan Dicks via cctalk <cctalk@classiccmp.org> wrote: > On Sat, Jan 27, 2018 at 4:34 PM, Jules Richardson via cctalk > <cctalk@classiccmp.org> wrote: >> Success! > > Congratulations! > >> I'd left the rear panel console settings how they were when I got the >> machine, I mean 'T' for terminal, right? Wrong... arrow for terminal, 'T' >> for "sit there alternating between F and 9, and driving Jules insane" ;) > > 'T' is 'Loop Test'...
http://www.bitsavers.org/pdf/dec/vax/630/ AX-GLBAA-MN_MicroVAX_II_630QB_Technical_Manual_Nov85.pdf Page 37 of the PDF, page 2-6, Figure 2-2, CPU Patch Panel Insert. Might be helpful to print out a copy of that figure and tape it to the back of the BA123. I can never remember what the rotary and toggle switch positions mean. > Just be sure to follow the grant chain - the BA23 and BA123 have a > hybrid backplane where the first few slots are CD slots and the rest > are serpentine (3 CD slots for BA23, 5 CD slots for BA123). First 4 slots of a BA123 are Q22/CD, not the first 5. Page 22 of the PDF, page 1-11, Figure 1-9 Backplane Grant Continuity of the same manual referenced above.