On 01/21/2018 01:25 PM, Jules Richardson via cctalk wrote:
So, I picked up (and I did just carry it into the house, and now I hurt) a Microvax II from another list member yesterday.
OK, the top PSU of the pair in this machine appears to be healthy. The bottom one, however, sits at around 2.5V on both the +5V and +12V outputs. That's without any cards, and the card-cage fan / temperature sensor unplugged, i.e. just with my dummy loads in place, so it looks like that PSU has issues (oh, and I tried decoupling the PSU from the backplane and loading it via the drive connector, so it doesn't appear to be a backplane issue).
I expect it's fixable, but I'm unsure what the system may have done at the point it originally failed, given that it was responsible for both the card-cage fan and the temperature sensor - hopefully it didn't sit there for hours with no card cooling, no overheat sensor, and with power applied to [at least some of] the cards via the still-working PSU.
Jules