At 04:03 AM 8/1/2016, drlegendre wrote:

>Non-polar caps are used in locations where they must pass AC.

Conventional polarized aluminum and tantalum capacitors are also used in 
locations where they must pass AC, such as interstage coupling capacitors and 
bypass capacitors, not to mention electrolytics as power supply filter 
capacitors. Any capacitor that could not pass AC would not be a capacitor.

There are two principal situations where non-polar electrolytics are used:

1) When there is no constant DC offset to the applied voltage - if the voltage 
applied to an electrolytic capacitor reverses the capacitor can be damaged. 
When there is no constant DC offset the second reason can come into play:

2) When a large value non-polarized electrolytic can, as previously noted, cost 
less than a large film, oil-filled, or other non-polar capacitor.

Some of us still deal daily with analog circuitry at work.

Dale H. Cook, Radio Contract Engineer, Roanoke/Lynchburg, VA
http://plymouthcolony.net/starcityeng/index.html 

Reply via email to