On Sun, 30 Aug 2015, ben wrote:
On 8/30/2015 6:32 PM, Tothwolf wrote:

On page 5, they describe 0.0031" 40 AWG magnet wire being reduced to 0.002" after soldering with 60/40 tin-lead solder. That 0.0011" reduction is basically 1/3 of the diameter of the wire. This explains the failures of the enamel wires in CHM's IBM 1620.

Copper erosion from tin is something I'd never really given a lot of thought to, but it will certainly be something I keep in mind from now on.

But is that the case? Would not heat induced failure be the real case here as I suspect that a amp or two of current is flowing that now very thin thread of wire? Digging though the doc's and a little calculation clear this up.

My guess is that over time the thinned wires broke due to a combination of vibration and thermal fatigue. Vibration while transporting the system to CHM may well have been what ultimately caused them to break.

Reply via email to