> Oh, sorry, didn't realize they used switchers for the PDP-11s.

There have been _many_ DEC PSU designed used for the PDP11. I think all of them 
used some 
kind of switching regulator for the +5V line. A quick glance at the printsets 
will settle it..

> However I was talking with a friend of mine last night about my error,
> and he told me that the switching supplies for the PDP-11s were very
> unreliable back in the day. He often had to troubleshoot the machines
> back then. A common failure was caused by static electric shock to the
> machine would blow the supply. NO carpets allowed!!

That is (a) meaningless and (b) totally contrary to mine (and others) 
experiences.

It's meaningless because there are so many 'PDP11' power supplies. There are 
some which use
a mains transformer followed by step-down switching regulators. There are some 
which are more
conventional SMPSUs, rectifying the mains and chopping the 350V so produced. 
There are some which
are multiple versions of that in one box (and at least one of those has a 
switching supply running off the
350V DC rail which produces a single 36V output which is then regulated with 
more switching regulators).

I do not believe all those designs have the same failure modes, or responses to 
static damage.

However, I have worked on many PDP11s, with all sorts of PSUs. Now admittedly I 
am careful about 
static, even working on bipolar circuitry. But not to the point of being silly 
about it. And I will state that I
have never damaged (or even caused to trip) a PDP11 PSU by a static zap to any 
of the output rails. And 
if a static zap to the casing of the machine damages the supply I would want to 
check the mains earthing 
(grounding) -- preferably before a fault causes somebody to get killed.

-tony

Reply via email to