Dear Claire, I am not a Phenix expert, but to me the discrepancy lies in the resolution ranges reported. The completeness of Depositor goes to 2.1 Å, while the completeness of EDS goes to 1.92 Å. Could it be that the cutoff of 2.1 Å was used for refinement, while the data were processed to 1.92 Å?
Best, Herman Von: CCP4 bulletin board [mailto:CCP4BB@JISCMAIL.AC.UK] Im Auftrag von Claire Smith Gesendet: Mittwoch, 11. Januar 2017 23:32 An: CCP4BB@JISCMAIL.AC.UK Betreff: [ccp4bb] PDB validation of structure factors Hello, I am trying to run the PDB validation report for a structure that I have refined in Phenix (data was analyzed with Xtriage). However, the run reports a discrepancy on the completeness of data, as follows: % Data completeness 97.4 (29.08-2.10) Depositor (in resolution range) 87.5 (29.08-1.92) EDS Why this discrepancy? Thanks so much, Claire