Try refining without disulfide bond - from the way density looks it might work. 
 Whether this is what happens in vivo is a different question entirely. 


Sent on a Sprint Samsung Galaxy S® III

<div>-------- Original message --------</div><div>From: Eze Chivi 
<ezech...@outlook.com.ar> </div><div>Date:06/02/2014  1:08 AM  (GMT-05:00) 
</div><div>To: CCP4BB@JISCMAIL.AC.UK </div><div>Subject: [ccp4bb] negative 
density around disulfide bond </div><div>
</div>Hello, when I refine my structure, I see negative density around the 
disulfide bond. I have 7 copies per ASU, and I can see this density in many of 
them. In some cases, I see positive density also (negative in the center of the 
straight line linking S atoms, and positive in both sides). What can I try to 
solve it? Is it due to radiation damage? Alternative conformation (partial 
oxidation)? Incorrect disulfide geometry parameters? My resolution is 2.1 A, 
R/Rfree are around 0.220/0.243, and similar results with refmac5, phenix and 
PDBREDO. Please find two example pictures in attachment.
Thanks for your help!


Ezequiel

Reply via email to